Identification of nitric oxide in serum and plasma of blood human. Metod of high pressure liquid chromatography

   
Kobyliansky A.G.1, Kuznethsova T.V.1, Soboleva G.N.1, Bondarenko O.N.2, Pogorelova O.A.1, Titov V.N.1, Masenko V.P.1

1. Russian Cardiology Research Complex
2. Endocrinology Research center of Russia
Section: Experimental/Clinical Study
PubMed Id: 16119088
Year: 2003  Volume: 49  Issue: 6  Pages: 597-603
Two methods of measurement of nitrite and nitrate determination in human serum and plasma (a colorimetric method based on Griess reaction and a HPLC method) have been compared HPLC method revealed extremely low level of nitrates blood plasma, which was roughly the same (about 3 mM or less) in healthy donors,and patients with diabetes and hypertension. The level of nitrates in group of healthy donors (29.9 ± 2.8 mM) is lower than in patients with diabetes this level is equal (58.6 ± 6.9 mM), and in patients with hypertension (35.4 ± 2.5 mM). Comparison of data obtained by colorimetric and HPLC methods revealed close correlation (r=0.77, р < 0,001). Methodical reuqirements for preparation of samples of serum and plasma of blood for analysis and correct intepretation of results are discussed in view of biochemical properties of nitric oxide molecule
Download PDF:  
Citation:

Kobyliansky, A. G., Kuznethsova, T. V., Soboleva, G. N., Bondarenko, O. N., Pogorelova, O. A., Titov, V. N., Masenko, V. P. (2003). Identification of nitric oxide in serum and plasma of blood human. Metod of high pressure liquid chromatography. Biomeditsinskaya Khimiya, 49(6), 597-603.
References  
 2024 (vol 70)
 2023 (vol 69)
 2022 (vol 68)
 2021 (vol 67)
 2020 (vol 66)
 2019 (vol 65)
 2018 (vol 64)
 2017 (vol 63)
 2016 (vol 62)
 2015 (vol 61)
 2014 (vol 60)
 2013 (vol 59)
 2012 (vol 58)
 2011 (vol 57)
 2010 (vol 56)
 2009 (vol 55)
 2008 (vol 54)
 2007 (vol 53)
 2006 (vol 52)
 2005 (vol 51)
 2004 (vol 50)
 2003 (vol 49)